Calculates repeatability and systematic bias of a gauge against a reference part.
How to use the result
Check the definition of the dimension and datum conditions on the drawing. The calculator does not replace inspection of the specific part.
Formulas
Cg = 0,2 · T / (6s)Cgk = (0,1 · T − |mean − reference|) / (3s) Sources: Measurement system capability, Type 1 convention with 20% tolerance share; not an ANOVA gauge R&R.